CAM-CRP-1064 Unable to process the PKCS #7 data because of an internal error

View previous topic View next topic Go down

CAM-CRP-1064 Unable to process the PKCS #7 data because of an internal error

Post  Guest on Thu Jun 09, 2011 7:05 pm

I am encountering the error on Content Manager that "CAM-CRP-1064 Unable to process the PKCS #7 data because of an internal error." Can anyone answer?


Last edited by saravanan.vajjiravel on Thu Jun 09, 2011 7:10 pm; edited 1 time in total

Guest
Guest


Back to top Go down

CAM-CRP-1064 Unable to process the PKCS #7 data because of an internal error.

Post  Guest on Thu Jun 09, 2011 7:09 pm

The cognos configuration needs to be redone from scratch.
Steps to be followed:

1. Open the Cognos Configuration Tool and make a note of all the settings that you have modified (take screen shots etc.)
2. Close cognos configuration and then rename the crnstartup.xml to crnstartup.xml_old in the <crninstall>/configuration folder.
3. In the <crninstall>/configuration folder, rename the csk, encryptkeypair, signkeypair folders.
4. Restart cognos configuration and re-enter all the configuration changes you had noted in step 1.
5. Save the configuration and start services.

Guest
Guest


Back to top Go down